A cost effective development of an ultrasonic A-scans database for high-temperature hydrogen attack

(2008) A cost effective development of an ultrasonic A-scans database for high-temperature hydrogen attack. NDT & E International, 41 (3). pp. 163-168.

Full text not available from this repository.

Abstract

Successful application of the rich collection of classification algorithms to non-destructive testing signals depends heavily on the availability of adequate and representative sets of training examples, whose acquisition can often be very expensive and time consuming. In this paper, an out-of-service pressure vessel known to have lots of high-temperature hydrogen attack defects is used to develop in a cost effective manner a database of ultrasonic A-scan signals. To test how adequate and representative these sets of A-scan signals are, a basic feature extraction method coupled with a primitive classifier is shown to distinguish accurately the hydrogen attack from geometrically similar defects.

Item Type: Article
Subjects: Electrical
Department: College of Engineering and Physics > Electrical Engineering
Depositing User: Obaid-Ur-Rehman Khattak
Date Deposited: 29 Mar 2008 06:59
Last Modified: 01 Nov 2019 13:25
URI: http://eprints.kfupm.edu.sa/id/eprint/802