Impact Of Scale Build-Up Models On Energy Utilization In Heat Exchangers

Impact Of Scale Build-Up Models On Energy Utilization In Heat Exchangers. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 23. pp. 999-1005.

[img]
Preview
PDF (A research paper on : Impact Of Scale Build-Up Models On Energy Utilization In Heat Exchangers)
impact_of_scale_build_up_models_on_energ_duffuaa_isi_000083078100007.pdf

Download (26kB) | Preview

Abstract

In this paper an energy utilization index is presented. It is used to investigate the impact of scale build-up in heat exchange equipment. The investigation is carried out using several scale build-up models. The models employed in this paper are the linear, logarithmic, and the asymptotic one. It has been demonstrated by a realistic example that the type of scale build-up model assumed greatly affects energy utilization and maintenance scheduling for heat exchange equipment. Copyright (C) 1999 John Wiley Sons, Ltd.

Item Type: Article
Subjects: Systems
Department: College of Computing and Mathematics > lndustrial and Systems Engineering
Depositing User: SYED AMEENUDDIN HUSSAIN
Date Deposited: 11 Jun 2008 07:39
Last Modified: 01 Nov 2019 13:29
URI: http://eprints.kfupm.edu.sa/id/eprint/1961