Direct load control using programmable logic controller.

Suhail, Mohammed Abdallah. (1997) Direct load control using programmable logic controller. Masters thesis, King Fahd University of Petroleum and Minerals.

[img]PDF
3356Kb

Arabic Abstract

-

English Abstract

Increasing the generation capacity and the transmission and distribution network as the demand grows are not sufficient on the long term basis. Demand is increasing faster at peak times than at other times. Besides, it takes several years to build a new power plant. Investments in peak generation as well as in transmission and distribution are not economically justified. For many utilities, it is more cost-effective to fully utilize what they have rather than try to build new power plants. More and more utilities are extending their activities into the customer's side. They are implementing the Demand Side Management (DSM) programs. The electricity distribution companies use either the Direct Load Control (DLC) or the indirect load control. There are different systems to apply the DLC. However, these systems suffer from shortcomings. A new DLC system is proposed in this thesis to overcome the drawbacks of the existing systems. A new DLC system is designed in this thesis. It is proposed to use this system as one of the alternatives of the DSM programs. The proposed DLC system satisfies the utility objectives and the customer requirements. The system has three main parts. The first part is a master station center at the utility side. It consists of a PC. The second part is the control device that is installed at the customer side. It is a Programmable Logic Controller (PLC). The third part is the interface circuits between the control device and the PC, and between the PLC and the loads. Two sophisticated programs are developed to serve the purpose of the proposed DLC system. One is stored in the PLC to direct control the customer loads. The other is used as user interface and PC protocol to control the installed PLC at the customer side. The control strategy is done through different scenarios. A prototype system is designed, implemented and evaluated. The proposed DLC system is studied on a real life case. The results of the experiments and the study show that there is a demand reduction in the load curve. The proposed DLC system meets the objective that it is designed for.



Item Type:Thesis (Masters)
Date:September 1997
Date Type:Completion
Subjects:Electrical
Divisions:College Of Engineering Sciences > Electrical Engineering Dept
Creators:Suhail, Mohammed Abdallah.
Committee Advisor:El-Amin, Ibrahim M.
Committee Members:Al-Ali, Abdul Rahman K. and Abdel-Magid, Youssef L. and Habiballah, Ibrahim O.
ID Code:10397
Deposited By:KFUPM ePrints Admin
Deposited On:22 Jun 2008 17:03
Last Modified:30 Apr 2011 15:32

Repository Staff Only: item control page